LCMS - Bruker Impact II

BrukerImpactII

The Bruker impact II is an ultra-high-resolution quadrupole time-of-flight liquid chromatography–tandem mass spectrometry system (LC–QTOF–MS/MS). Combined with appropriate sample preparation and liquid chromatographic separation, it enables highly sensitive, high-resolution, and high-mass-accuracy full-scan analysis of metabolites in complex biological samples. Using high-resolution quadrupole time-of-flight mass spectrometry, the system can broadly detect both known and unknown small-molecule compounds in a single analytical run. Accurate mass measurements, isotopic distribution patterns, and tandem mass spectrometric fragmentation data can be used for molecular formula prediction, compound annotation, and structural identification. The system is therefore well suited for high-sensitivity, high-mass-accuracy untargeted metabolomics analysis of complex biological samples.


Experimental / Analytical Items

1.Untargeted Metabolomics

2.Lipidomics

3.Metabolite Annotation


Contact person: Cheng-Yu Hung, Ext: #3539, Email: aruhung@gap.cgu.edu.tw

LCMS - Waters HDMS G1

WatersHDMSG1

The Waters SYNAPT G1 is a high-resolution quadrupole time-of-flight liquid chromatography–tandem mass spectrometry system (LC–QTOF–MS/MS). Combined with appropriate sample preparation and high-performance liquid chromatographic separation, it enables high-mass-accuracy untargeted metabolomics analysis of plasma, serum, urine, cells, tissues, and other complex biological samples. The system is suitable for highly sensitive and high-mass-accuracy untargeted metabolomics analysis of complex biological matrices.


Experimental / Analytical Items

1.Untargeted Metabolomics

2.Lipidomics

3.Metabolite Annotation


Contact person: Cheng-Yu Hung, Ext: #3539, Email: aruhung@gap.cgu.edu.tw

LCMS - SCIEX 6500

SCIEX6500

The SCIEX 6500 is a highly sensitive triple quadrupole liquid chromatography–tandem mass spectrometry (LC–MS/MS) system designed primarily for the selective detection and accurate quantification of known target compounds. Using multiple reaction monitoring (MRM), the system monitors specific precursor-to-product ion transitions, thereby improving analytical selectivity and minimizing matrix interference in complex biological samples.

Experimental / Analytical Items
1.Targeted metabolomics analysis
2.Quantification of drugs, drug metabolites, and biomarkers
3.Preclinical studies and analytical method validation
4.High-throughput, multi-analyte quantitative analysis
Contact person: Hsiang-Yu Tang, Ext: #3539, Email: tangshyu@gap.cgu.edu.tw
 

LCMS - Waters Xevo TQ-S

WatersTQS

The Waters Xevo TQ-S is a highly sensitive triple quadrupole liquid chromatography–tandem mass spectrometry (LC–MS/MS) system primarily used for the highly selective and accurate quantification of known small-molecule compounds. By combining multiple reaction monitoring (MRM) with high-performance liquid chromatographic separation, the system enables reliable detection and concentration determination of target metabolites in complex biological matrices.


Experimental / Analytical Items

1.Targeted metabolomics analysis

2.Quantitative analysis of drugs and their metabolites

3.Biomarker validation and analysis of clinical research samples

4.Multi-analyte quantitative analysis


Contact person: Hsiang-Yu Tang, Ext: #3539, Email: tangshyu@gap.cgu.edu.tw

Nuclear Magnetic Resonance

NMR

Bruker AVANCE III HD 600 MHz NMR
    H/C/N TCI CryoProbe
    H/C/N TXI Probe
Ssample Jet (5mm and 3mm sampleshuttles)

Comprehensive detection, non-destructive analysis, identification, and quantification of small-molecule metabolites in biological samples (such as urine, blood, cells, or tissue extracts).

Experimental / Analytical Items
1.One-dimensional 1H及13C liquid-state NMR
2.Two-dimensional 1H / 13C / 15N liquid-state NMR

3.Multidimensional 1H / 13C / 15N liquid-state NMR


Contact person: Chun-Ming Fan, Ext: #5019, Email: jimmyf@gap.cgu.edu.tw