Move to the main content

Agilent BioTek LionHeart FX

LionHeart FX
Agilent BioTek LionHeart FX 1 set
(LED cube DAPI & GFP & TexasRED & CY5)

Automated camera system for cell fluorescence, bright field, high contrast bright field and color bright field. Performimage processing such as sitching, overlaying or background removal. Final analysis to get qualitative or quantitative data.

Ms. Tsui-Chih Hsieh#

Tel:
5191



SARTORIUS Octet RED96

Octet RED96

SARTORIUS Octet RED96 1 set

The interaction between biomolecules and biomolecular kinetic and affinity was analyzer by BLI(Bio-Layer Interferomerty). The ka, kd and KD were analyzed. After the test, the sample can be recycled. Can be used for antigen-antibody, proteinmolecules and drug-protein, receptor-ligand, nuclear acid-nuclear acid and other molecules between the interaction analysis.

Ms. Tsui-Chih Hsieh#

Tel:
5191


Seahorse XF Pro

Seahorse XF Pro
Agilent Seahorse XF Pro 1 set

The Seahorse XF Pro utilizes a 96-well microplate format and label-free solid-state sensor technology to monitor cellular bioenergetics. By detecting real-time changes in oxygen and hydrogen ion concentrations in the extracellular microenvironment without direct contact with or damage to the cells, the instrument continuously measures the oxygen consumption rate (OCR) and extracellular acidification rate (ECAR). These parameters provide dynamic insights into cellular energy metabolism, including mitochondrial respiration and glycolytic activity. 

Ms. Tsui-Chih Hsieh#

Tel:
5191

PerkinElmer EnSpire 2300

EnSpire 2300

PerkinElmer EnSpire 2300 1 set


Measureable category is ALPHA 、Luminscence and Absorbance。





Ms. Tsui-Chih Hsieh#

Tel:
5191



High Content Analysis

High Content Analysis
GE INCell Analyzer 1000 1 set
GE Investigator 1 set

IN Cell Analyzer 1000

    (1)Lamp:Xenon 100W 
    (2)Microscope:Nikon TE 2000 
    (3)Objective:4X/0.2、10X/0.45、
                             20X/0.45、40X/0.6
    (4)CCD Camera
    (5)Plate type:6-96 well plate
Investigator
    (1)Workstation version 3.6
    (2)Developer version 1.8


Ms. Tsui-Chih Hsieh#

Tel:
5191



X-ray film processor


X-ray film processor
Protec Optimax, Film Processor 2 set

The rinseable X-ray sheet has a maximum size of 35x43 cm (14x17 inch) and a minimum of 10x10 cm (4x4 inch) for about 30 to 60 seconds.




Mr. Hsiu-Yuan Liao
#Tel:5970



Sterilizer

733HC   CASTLE MC 3533 110
GETINGE 733HC 955 liter 2 set

CASTLE M/C 3533 250 liter 1 set

Can set the temperature (100 ~ 135℃) and drying time (0 ~ 12 hours). The average disinfection of each operation takes about 60 to 90 minutes (dry time separately)




Mr. Yi-Lin Wen#

Tel:
5256