Move to the main content

Agilent BioTek LionHeart FX

LionHeart FX
Agilent BioTek LionHeart FX 1 set
(LED cube DAPI & GFP & TexasRED & CY5)

Automated camera system for cell fluorescence, bright field, high contrast bright field and color bright field. Performimage processing such as sitching, overlaying or background removal. Final analysis to get qualitative or quantitative data.

Ms. Tsui-Chih Hsieh#

Tel:
5191



LionHeart FX

1.Lamp

High power LED

2.Objective

Zeiss 2.5X/0.12

Olympus 4X/0.1310X/0.320X/0.4540X/0.6

3.Plate type

Observable 6-384 plateslidechamber slide

3.5cm dish6cm dish

4.Environment

Room temperature to 40and CO2 5%

5.Filter cube

Excitation

Emission

DAPI

377/50X

447/60M

GFP

469/35X

525/39M

TexasRED

586/15X

647/57M

CY5

628/40X

685/40M


SARTORIUS Octet RED96

Octet RED96

SARTORIUS Octet RED96 1 set

The interaction between biomolecules and biomolecular kinetic and affinity was analyzer by BLI(Bio-Layer Interferomerty). The ka, kd and KD were analyzed. After the test, the sample can be recycled. Can be used for antigen-antibody, proteinmolecules and drug-protein, receptor-ligand, nuclear acid-nuclear acid and other molecules between the interaction analysis.

Ms. Tsui-Chih Hsieh#

Tel:
5191




Octet RED96

1.Affinity

Range1mM-10pM

2.Molecular Weight

150Da

3.Minimum Sample Volume

200uL

4.Maxmum Simultaneous Reads

8

5.Temperature Control

Ambient+4℃〜40


PerkinElmer EnSpire 2300

EnSpire 2300

PerkinElmer EnSpire 2300 1 set


Measureable category is ALPHA 、Luminscence and Absorbance。





Ms. Tsui-Chih Hsieh#

Tel:
5191



EnSpire ALPHA 2300

1.ALPHA

Excitation 680nm

Emission 615nm

2.Luminescence

3.Absorption

Visible light 260nm

Visible light 280nm

Visible light 405nm

Visible light 450nm

Visible light 540nm

Visible light 595nm


High Content Analysis

High Content Analysis
GE INCell Analyzer 1000 1 set
GE Investigator 1 set

IN Cell Analyzer 1000

    (1)Lamp:Xenon 100W 
    (2)Microscope:Nikon TE 2000 
    (3)Objective:4X/0.2、10X/0.45、
                             20X/0.45、40X/0.6
    (4)CCD Camera
    (5)Plate type:6-96 well plate
Investigator
    (1)Workstation version 3.6
    (2)Developer version 1.8


Ms. Tsui-Chih Hsieh#

Tel:
5191



INCell Analyzer 1000

1.Lamp

Xenon 100W

2.Objective

Nikon 4X/0.210X/0.4520X/0.4540X/0.6

3.Plate type

Observable 6-96 plateslide

4.Filter

Excitation

Emission

350/50X

455/50M

480/40X

525/36M

555/25X

620/60M

645/30X

705/72M


X-ray film processor


X-ray film processor
Protec Optimax, Film Processor 2 set

The rinseable X-ray sheet has a maximum size of 35x43 cm (14x17 inch) and a minimum of 10x10 cm (4x4 inch) for about 30 to 60 seconds.



Mr. Hsiu-Yuan Liao
#Tel:5970


Sterilizer

733HC   CASTLE MC 3533 110
GETINGE 733HC 955 liter 2 set

CASTLE M/C 3533 250 liter 1 set

Can set the temperature (100 ~ 135℃) and drying time (0 ~ 12 hours). The average disinfection of each operation takes about 60 to 90 minutes (dry time separately)




Mr. Yi-Lin Wen#

Tel:
5256